Appendix E – Communicating and Reporting
Samsung Group Report
When programming groups in the Samsung 6500 register, the option ‘Add to
Group Total’ refers only to reporting at the register. When a group
report is selected at the register, the total is calculated at report time,
selecting only the groups flagged for totals. When PC/POLL requests the groups
from the 6500, the register sends the data for each group, but does not include
the group total. The total on the PC/POLL group report is the sum of all groups
sent by the register.
PLU by Group Report
The Samsung can do a PLU by Group Report. However, this feature is only
available at the register during report time. Within Polling Version 6.2 an
emulated PLU by Group Report has been added for all registers.
Error Code 47
Error Code 47 (Range Over) from the ECR usually occurs when sending a program
that has more items than the memory allocation in the ECR allows. For example,
trying to send 1,200 PLUs when the ECR’s memory can only accommodate 1,000
will cause this error. Changing the memory allocation settings at the ECR to
allow for the additional items will be necessary.
Error Code 55
Getting Error Code 55 (BAD FUNC) from the ECR is most often caused by
attempting to do a Daily report using a Daily period. The Samsung does not
support a Daily/Daily report. You can use a Daily/Monthly or a Daily/Periodic
instead. See Appendix B – Action Batches.
Error Code 56
The Samsung Error Code 56 (BUSY) does not mean failure to communicate. Every
Z report will set the Consolidation flag but does not reset the data. This
prevents a second consolidation, which would overwrite and lose the data.
If possible, run the first poll that created this error. This will
collect the information, clear the totals, and allow normal operation to
resume. Otherwise, put the register in Z Mode. Press 18 Subtotal to
clear all data in the buffer. This method will case you to lose the information
contained in the poll that errored!
Back to
Appendices/Cabling home
|